A searchable database of maritime OT equipment with known vulnerabilities — covering navigation systems, engine automation, power management, and vessel control CBS from major marine vendors. Search by vendor, product family, or CVE ID to check whether equipment on your vessel has documented vulnerabilities requiring attention or patch management action.

Searchable by vendor CVE referenced Marine OT vendors Continuously updated
Audit Level: Tactical
Records optimised: 01.07.2026 22:57 UTC

CVE-2021-22283 — ABB: Relion protection relays - 611 series

Published: 2023-02-28 | Updated: 2025-03-07

MEDIUM 6.2
Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1, ABB Relion protection relays - 620 series IEC/CN 2.0, ABB Relion protection relays - 620 series IEC/CN 2.0 FP1, ABB Relion protection relays - REX640 PCL1, ABB Relion protection relays - REX640 PCL2, ABB Relion protection relays - REX640 PCL3, ABB Relion protection relays - RER615, ABB Remote Monitoring and Control - REC615, ABB Merging Unit- SMU615 allows Communication Channel Manipulation.This issue affects Relion protection relays - 611 series: from 1.0.0 before 2.0.3; Relion protection relays - 615 series IEC 4.0 FP1: from 4.1.0 before 4.1.9; Relion protection relays - 615 series CN 4.0 FP1: from 4.1.0 before 4.1.8; Relion protection relays - 615 series IEC 5.0: from 5.0.0 before 5.0.12; Relion protection relays - 615 series IEC 5.0 FP1: from 5.1.0 before 5.1.20; Relion protection relays - 620 series IEC/CN 2.0: from 2.0.0 before 2.0.11; Relion protection relays - 620 series IEC/CN 2.0 FP1: from 2.1.0 before 2.1.15; Relion protection relays - REX640 PCL1: from 1.0.0 before 1.0.8; Relion protection relays - REX640 PCL2: from 1.1.0 before 1.1.4; Relion protection relays - REX640 PCL3: from 1.2.0 before 1.2.1; Relion protection relays - RER615: from 2.0.0 before 2.0.3; Remote Monitoring and Control - REC615: from 1.0.0 before 2.0.3; Merging Unit- SMU615: from 1.0.0 before 1.0.2.

CVSS VECTOR: CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

NVD Record ↗ | Vendor Advisory / Fix ↗

← Back to full Vulnerable Assets Library

Get new CVE entries like these in your inbox weekly. Subscribe →

Disclaimer & Methodology

The Marine OT Vulnerable Assets Library is a curated repository of security advisories identified through automated heuristic filtering. Users should verify hardware revisions with manufacturers before patching.

Scroll to Top